欢迎访问《硅酸盐通报》官方网站,今天是

硅酸盐通报 ›› 2026, Vol. 45 ›› Issue (9): 3117-3125.DOI: 10.16552/j.cnki.issn1001-1625.2026.0268

• 水泥混凝土 • 上一篇    下一篇

冲击荷载下组合梁栓钉连接件动态力学性能与失效机理研究

冯俊豪(), 胡昊, 余振鹏, 杜晓庆, 张永平()   

  1. 上海大学力学与工程科学学院,上海 200444
  • 收稿日期:2026-03-21 修订日期:2026-04-21 出版日期:2026-09-15 发布日期:2026-10-09
  • 通信作者: 张永平,博士,副教授。E-mail:zhangyongping@shu.edu.cn
  • 作者简介:冯俊豪(2001—),男,硕士研究生。主要从事钢-混组合梁剪力连接件的研究。E-mail:lm15851870396@163.com
  • 基金资助:
    国家自然科学基金(52008238)

Dynamic Mechanical Properties and Failure Mechanism of Headed Stud Connectors in Composite Beams under Impact Loading

FENG Junhao(), HU Hao, YU Zhenpeng, DU Xiaoqing, ZHANG Yongping()   

  1. School of Mechanics and Engineering Science,Shanghai University,Shanghai 200444,China
  • Received:2026-03-21 Revised:2026-04-21 Published:2026-09-15 Online:2026-10-09

摘要:

为揭示极端冲击作用下钢-混凝土组合梁栓钉连接件的动态力学响应与失效机理,本文采用静力推出试验与落锤冲击试验相结合的方法,开展其动态抗剪性能试验研究。试验系统获取了不同落锤高度下试件的冲击力和位移时程曲线,并分析了试件破坏模式与动态抗剪承载力演化规律。结果表明,栓钉连接件的力学性能在落锤冲击作用下呈明显的冲击高度相关性与应变率效应,其破坏模式、冲击力峰值、位移响应均随冲击能量输入的提高而发生显著变化。在低能量冲击下,栓钉连接件以弹性响应为主;在中等能量冲击下,栓钉连接件出现单侧栓钉脆性剪断并伴随局部混凝土压碎的非对称破坏;在高能量冲击下,栓钉连接件两侧栓钉均发生脆性剪切断裂,界面完全失效。随着落锤冲击高度增大,冲击力峰值与残余位移均明显增加,动态抗剪承载力相对静载提高72%~176%。基于试验分析结果建立了动态增大系数(DIF)与应变率的关系,基于DIF提出了栓钉连接件动态抗剪承载力计算方法,并与经典的栓钉承载力计算模型进行对比验证。研究可为组合结构在撞击、爆炸等极端作用下的抗剪连接设计与安全评估提供参考。

关键词: 钢-混凝土组合梁, 栓钉连接件, 冲击荷载, 承载力计算, 动态增大系数(DIF), 失效机理

Abstract:

To reveal the dynamic mechanical response and failure mechanism of headed stud connectors in steel-concrete composite beams under extreme impact loading, this study conducted experimental investigations on their dynamic shear performance through a combination of static push-out tests and drop-weight impact tests. The impact force and displacement time-history curves of the specimens under different drop heights were systematically obtained, and the failure modes and evolution of dynamic shear bearing capacity were analyzed.The results show that the mechanical performance of the headed stud connectors under drop-weight impact loading exhibits clear drop-height dependence and strain-rate effects. The failure mode, peak impact force, and displacement response vary significantly with increasing input impact energy. Under low-energy impact, the headed stud connectors mainly remain in an elastic response stage. Under medium-energy impact, asymmetric failure occurs, characterized by brittle shear fracture of headed studs connectors on one side accompanied by local concrete crushing. Under high-energy impact, brittle shear fracture occurs in the headed studs connectors on both sides, leading to complete interface failure.With increasing drop height, both the peak impact force and residual displacement increase markedly, and the dynamic shear bearing capacity is 72% to 176% higher than the static bearing capacity. Based on the experimental results, the relationship between the dynamic increase factor (DIF) and strain rate is established. A DIF-based calculation method for the dynamic shear bearing capacity of headed stud connectors is then proposed and validated through comparison with classical bearing capacity models for headed stud connectors. This study can provide a reference for the design and safety assessment of shear connections in composite structures subjected to extreme actions such as impact and explosion.

Key words: steel-concrete composite beam, headed stud connector, impact load, bearing capacity calculation, dynamic increase factor (DIF), failure mechanism

中图分类号: